Sign In | Join Free | My burrillandco.com
Home > Multifunction Process Calibrator >

100MV Digital Signal Generator Analog Transmitter Source Simulator

    Buy cheap 100MV Digital Signal Generator Analog Transmitter Source Simulator from wholesalers
     
    Buy cheap 100MV Digital Signal Generator Analog Transmitter Source Simulator from wholesalers
    • Buy cheap 100MV Digital Signal Generator Analog Transmitter Source Simulator from wholesalers
    • Buy cheap 100MV Digital Signal Generator Analog Transmitter Source Simulator from wholesalers

    100MV Digital Signal Generator Analog Transmitter Source Simulator

    Ask Lasest Price
    Brand Name : VICTOR
    Model Number : VICTOR 71A
    Certification : CE
    Price : USD55/pc
    Payment Terms : T/T, Western Union, L/C, Paypal
    Supply Ability : 1000pcs available
    Delivery Time : 5 to 30 days
    • Product Details
    • Company Profile

    100MV Digital Signal Generator Analog Transmitter Source Simulator

    100MV Digital Signal Generator Analog Transmitter Source Simulator


    VICTOR 71A l Signal Generator Current and voltage process calibrator Analog Transmitter Source Simulator


    Description

    This series of meters are categorized into the standard and thermocouple type. This manual is illustrated based on the thermocouple type.

    This series of meters has the following functions:

    • 100 mV, 30 V DC voltage measurement, 20 mA DC current measurement, and switching value measurement;
    • 100 mV, 30 V DC voltage output, 20 mA DC current output and SIMULATE output;
    • V, mA manual step output,automatic waveform output;
    • Simultaneous display of V, mA and percentage;
    • Loop detection function: It simultaneously provides the 24 V loop power supply and measures the current.

    The following functions are added to the thermocouple type:

    • Eight scale division (i.e., R, S, B, K, E, J, T and N) thermocouple measurement and output function;
    • Temperature display in Celsius degree and Fahrenheit degree;
    • Automatic and manual cold junction compensation function.

    Open-package Inspection

    Check the goods to see if they are damaged during delivery. Check if the goods are complete, and keep the packing materials for future delivery.

    This meter comes with the following standard accessories:

    • One pair of test leads (with alligator clips)

    • One manual

    • One 9 V alkaline battery (6LR61)


    Technical Specification

    General Characteristics

    Display refresh2~3 times/second
    Overload protection50mA/30V
    Working temperature and humidity range0~40 ºC and a relative humidity below 85% (no condensation)
    Storage temperature and humidity range-20 ºC~60 ºC and a relative humidity below 90% (no condensation)
    Precision ensures the temperature and humidity range23±5ºC and a relative humidity below 75% (no condensation)
    Temperature coefficient0.1 × basic precision/℃ (temperature range <18 ℃ or >28 ℃)
    Ambient conditions for useIndoor and outdoor use (not waterproof), with an elevation of 0~2000 m
    Outrange displayOL
    Battery kind9V (6LR61) alkaline battery one
    Power consumption

    When alkaline battery is used

    Loop current measurement and DC current output (SOURCE) 20mA (a load of 1000Ω): approx. 1000mVA

    Other work function: approx. 300mVA

    Low batteryDisplay battery sign
    Automatic shutdownNo operation for about 15 min by default
    Preheating time10 min
    Close the meter enclosure for calibrationNo need for internal adjustment
    Size147(L)×75(W)×42(D)mm
    WeightApprox. 230 g
    Calibration cycleOne year

    Detailed Precision Index of Measurement

    Measurement FunctionRangeMeasure RangeResolutionAccuracyNotes
    DC voltage100mV-10.0mV~110.0mV100uV0.2%+4

    • Input impedance: 30V: 300kΩ (nominal value)

    mV:>1MΩ (nominal value)

    • Common mode rejection: 50Hz or 60Hz >80dB

    • Series mode rejection: 50Hz or 60Hz > 40dB

    • Overvoltage protection:30V (peak to peak value)

    30V-5.00V~30.00V10mV0.2%+4
    DC current20mA0.00mA~22.00mA0.01mA0.2%+4

    • Overload protection: 50mA/30V

    • Load voltage: approx. 18mV/mA

    ThermocoupleR0°C~1760°C1°C0.2%+4• Thermocouple measurement adopts ITS-90 thermometric scale,whose precision does not include error of the cold junction compensation, and the impact of thermoelectrical potential
    S0°C~1760°C
    B400°C~1820 °C
    K-200°C~1370°C
    E-200°C~1000°C
    J-200°C~1200°C
    T-200°C~400°C
    N-200°C~1300 °C

    Detailed Precision Index of Output

    Output FunctionRangeOutput Setting RangeResolutionAccuracyNotes
    DC voltage100mV0.0mV~110.0mV100uV0.2%+4• Maximum output current 1mA
    10V0.00V~11.00V10mV0.2%+4• Maximum output current 5 mA (<10V)
    DC current20mA0.00~22.00mA0.01mA0.2%+4• 20mA maximum load: 1KΩ

    Analog transmitter

    SIMULATE

    -20mA0.00~-22.00mA0.001mA

    • External power supply: 5~28V

    • 20mA maximum load: 1KΩ

    Loop power supply LOOP24V±10%• Maximum output current 25mA
    ThermocoupleR0°C~1760°C1°C0.2%+4• Thermocouple measurement adopts ITS-90 thermometric scale,whose precision does not include error of the cold junction compensation, and the impact of thermoelectrical potential
    S0°C~1760 °C
    B400°C~1800°C
    K0°C~1350°C
    E0°C~700°C
    J0°C~950°C
    T0°C~400°C
    N0°C~1300°C
    Capacitive load≥0.01uF

    Technical Data

    ProjectVICTOR 71AVICTOR 71B
    SOURCEDC millivoltRange0~110mV0~110mV
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution100uV100uV
    DC voltageRange0 ~ 10V0 ~ 10V
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution10mV10mV
    DC currentRange0~22mA0~22mA
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution0.01mA0.01mA
    Sink currentRange0~22mA0~22mA
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution0.01mA0.01mA
    External power supply5 ~ 28V5 ~ 28V
    ThermocoupleRange8 types(R/S/K/E/J/T/B/N)
    Basic accuracy0.2%+4dgt
    Resolution1℃
    MEASUREDC millivoltRange-10~110mV-10~110mV
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution100uV100uV
    DC voltageRange-5~30V-5~30V
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution10mV10mV
    DC currentRange0~22mA0~22mA
    Basic accuracy0.2%+4dgt0.2%+4dgt
    Resolution0.01mA0.01mA
    Loop powerRange24V24V
    Basic accuracy10%10%
    Limit current25mA25mA
    ThermocoupleRange8types(R/S/K/E/J/T/B/N)
    Basic accuracy0.2%+4dgt
    Resolution1℃
    Other functionsManual Step Output
    Automatic Waveform Output
    Standard Quantity Per Carton12pcs12pcs
    Standard Carton Measurement430mm*350mm*22.50mm430mm*350mm*22.50mm
    Standard Carton Cross Weight7Kg7Kg

    Quality 100MV Digital Signal Generator Analog Transmitter Source Simulator for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: XI'AN BEICHENG ELECTRONICS CO.,LTD
    *Subject:
    *Message: