Sign In | Join Free | My burrillandco.com
Home > Multifunction Process Calibrator >

VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65

    Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
     
    Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers
    • Buy cheap VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 from wholesalers

    VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65

    Ask Lasest Price
    Brand Name : VICTOR
    Model Number : VICTOR 26
    Certification : CE
    Price : USD1250/pc
    Payment Terms : T/T, Western Union, L/C, Paypal
    Supply Ability : 1000pcs available
    Delivery Time : 5 to 30 days
    • Product Details
    • Company Profile

    VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65

    VICTOR26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V Loop Circuit IP 65 Protection Grade

    • Basic feature
    • A multifunctional on-spot process calibrator with high accuracy and high stability, which can provide powerful measurable functions, output and calibrates all parameters for all kinds of process.
    • Basic feature of input measurement
    • The max accuracy of measurement can reach 0.01%, and displays as 5 digits.
    • Measurement functions include: DC voltage, DC current, resistance, RTD, TC, frequency, pulse counting, switch volume, pressure, and pressure leakage ect.
    • Undertake two-wired, three-wired and four-wired resistance and RTD measurement.
    • Switch test of fast response allows capturing the process parameters for switching actions.
    • Data settle function: data-holding, zero, proportion, mean, Max/min value ect.
    • Built-in 24V loop circuit and loop current measurement
    • Basic feature of analog output
    • Max accuracy of output can reach 0.01%, and output displays as 6 digits.
    • Output functions include: DC voltage, DC current, analog resistance, RTD, TC, analog transmitter output, frequency, pulse counting, switch volume, and pressure output ect.
    • Output augment and decrease setting, and can connect or disconnect output, which is easy for operation.

    DCI output manual-step, auto-step and auto-ramping output functions.

    Built-in 24V loop circuit.

    • Two independent channels for measurement and input, allowing in-time measurement and outputs of process signals simultaneously; multiple data display to display input measurement value and output settings.
    • Facilitate pressure calibration by external a series of VPM-S digital pressure module through serial RS-232 injection (LEMO plug). There are abundant varieties and range specification of pressure modules to meet any pressure measurement needs. And the basic accuracy can reach 0.05%, and a variety of pressure units are available for pressure calibration.
    • Provide varieties of selectable temperature graduation. Built-in accurate temperature transmitter, with high accurate TC cold-compensation function, and RTD cold compensation can be selected both for connection or disconnection.
    • PC on-line communication function
    • The meter provides two ways to communicate with the user’s upper PC and can communicate by the infrared isolated serial commutation module of the compatible USB interface.
    • Supports SCPI commands of industrial standard, and can realize remote control of the meter by equipment driving software.
    • Note: the PC communication function is not available when the meter is communicating with the pressure module in HART communication function.
    • The meter is equipped with data storage with large capacity, to store as many as 1000(groups) data of field calibration. The data can be read from the meter or uploaded to the user’s PC.
    • The meter employs panel calibration technique, connects to standard device, undertakes panel calibration operation according to set range, and saves relevant calibrated data, fulfills the periodic calibration work stipulated by the meter to ensure the accuracy and performance.
    • The meter employs the navigation key to make increment or decrement of the setting value, which makes operation convenient and easy.
    • 3.2 inches TFT display screen, supporting multiple data display and intuitive interface.
    • Other functions: auto power-off, VF, auto turn- off for backlight, setting of backlight, data and time display and setting, ambient temperature detection, power frequency setting ect.
    • two ways of power supply
    • The instrument can supply power through the four 5th alkaline batteries in the battery case, or use the adaptor to supply.
    • Basic functions and performance(technical index)

    Input Measurement Function [adapt to one year after calibration 23℃±5℃,20~70% RH,accuracy=±(% readings + % range)]

    measurement functionrangemeasurement rangeresolutionaccuracyremark

    DC voltage

    DCV

    50mV

    -5.000mV~

    55.000mV

    1μV0.01+0.01Input resistance: about 100MΩ
    500mV

    -50.00mV~

    550.00mV

    10μV0.01+0.01
    5V

    -0.5000V~

    5.5000V

    0.1mV0.01+0.01Input resistance: about 1MΩ
    30V

    -5.000V~

    35.000V

    1mV0.01+0.01

    DC current

    DCI

    50mA

    -5.000mA~

    55.000mA

    1μA0.01+0.01shunt resistance: about 10Ω

    Ohms

    OHM

    (4W)

    500Ω0.00Ω~550.00Ω0.01Ω0.01+0.01

    500Ω about 1mA simulation

    5KΩ about 0.1mA simulation

    open-loop voltage: about 2.5V

    wire resistance is excluded in the accuracy

    5KΩ

    0.0000 KΩ~

    5.5000KΩ

    0.1Ω0.01+0.01

    frequency

    FREQ

    50KHz3Hz~50.00000KHz0.01Hz0.01+0.00004

    input resistance: more than 100 kΩ

    frequency sensitivity:

    square wave is 3V Vp-p at least

    50% duty ratio

    CPM180~3000000 CPM1CPM±2个字

    Thermal couple

    TC

    R*0°C~1767°C1°C

    0~500℃ : 1.8℃

    500~1767℃ : 1.5℃

    Employ ITS-90 temperature standard

    Errors for cold-end compensation is excluded in the accuracy

    S*0°C~1767°C
    K-100.0°~1372.0°C0.1°C

    -100.0~0.0℃ : 1.2℃

    0.0~1372.0℃ : 0.8℃

    E-50.0°C~1000.0°C

    -50.0℃~0.0℃ : 0.9℃

    0.0~1000.0℃ : 1.5℃

    J-60.0°C~1200.0°C

    -60.0~0.0℃ : 1.0℃

    0.0~1200.0℃ : 0.7℃

    T-100.0°C~400.0°C

    -100.0~0.0℃ : 1.0℃

    0.0~400.0℃ : 0.7℃

    N-200.0°~1300.0°C

    -200.0~0.0℃ : 1.5℃

    0.0~1300.0℃ : 0.9℃

    B*600°C~1820°C1°C

    600~800℃ : 2.2℃

    800~1000℃ : 1.8℃

    1000~1820℃ : 1.4℃

    L-60.0°C~900.0°C0.1°C

    -60.0~0.0℃ 0.7℃

    0.0~900.0℃ 0.5℃

    U-100.0°C~600.0°C0.1°C

    -100.0~0.0℃ 0.7℃

    0.0~600.0℃ 0.5℃

    Resistance temperature

    RTD


    Pt100

    385

    -200.0°C~800.0°C0.1°C

    -200.0~0.0℃ : 0.5℃

    0.0~400.0℃ : 0.7℃

    400.0~800.0℃ : 0.8℃

    Employ ITS-90 temperature standard

    Errors due to the mismatch of lead resistance for lead resistance, 3-wired or 4-wired measurements are excluded in the accuracy

    Pt1000

    385

    -200.0°C~630.0°C

    -200.0~100.0℃: 0.3℃

    100.0~300.0℃ : 0.5℃

    300.0~630.0℃ : 0.7℃

    Pt200

    385

    -200.0°C~630.0°C

    -200.0~100.0℃: 0.8℃

    100.0~300.0℃ : 0.9℃

    300.0~630.0℃ : 1.0℃

    Pt500

    385

    -200.0°C~630.0°C

    -200.0~100.0℃: 0.4℃

    100.0~300.0℃ : 0.5℃

    300.0~630.0℃ : 0.7℃

    Cu10-100.0°C~260.0°C1.8℃
    Cu50-50.0°C~150.0°C0.7℃

    Pulse counting

    PULSE

    100000 cycles1~100000cycles1cycle±2个字see the related indexes for frequency

    switch volume measurement

    SWITCH

    CLOSE / OPEN

    about 1mA simulation

    short circuit displays CLOSE

    open circuit displays OPEN

    the threshold value is about 200~300Ω

    Continuity test

    CONNECT

    500Ω≤ 50Ω vocalize0.01Ω

    500Ω

    about 1mA simulation

    Loop supply

    LOOP

    24 V10%

    short circuit protection

    Max circuit : 22 mA

    Max input voltage: 30 V DC

    output resistance: 250Ω nominal value

    Other features:

    • The valid temperatures of TC R, S, B range from 0 to 50°C when make manual compensation.
    • measurement speed ratio: twice / second
    • common mode rejection: 50Hz / 60Hz > 120 dB , series mode rejection: 50Hz / 60Hz > 60 dB
    • temperature coefficient: 0.1 x basic accuracy / ℃ (temperature range <18℃ or >28℃)
    • built-in temperature compensation transistor RJC, measuring range -10~50°C, the accuracy of measured temperature between 18 to 28°C is ±0. 5℃ , the accuracy of other measured temperature is ±1℃. Time for cold temperature is 10S/every time.
    • the Max voltage applied between V,Ω,Hz input terminals and COM terminals : 30Vpk
    • The maximum current of mA terminals: 100mA . mA input protection of mA terminals: 100mA/250V fast-melt.

    Simulation Output Function [adapt to one year after calibration 23℃±5℃, 20~70%RH ,accuracy=±(% settings + range %)]

    Output functionrangeOutput rangeresolutionaccuracyremark

    DC voltage

    DCV

    100mV-10.000~110.000mV1μV0.01+0.01Max output current 0.5mA
    1V-0.10000~1.10000V10μV0.01+0.01Max output current 2mA
    10V-1.0000~11.0000V0.1mV0.01+0.01Max output current 5mA

    Dc current

    DCmA

    30mA0.000~33.000mA1μA0.01+0.01

    In 33mA,

    the Max load is 1KΩ resistance

    in simulate transmitter,external power supply 5~28V

    Ohmn

    OHM

    400Ω0.00~400.00Ω0.01Ω0.01+0.01

    simulate current is ±0.05~0.3mA

    simulate current is ±0.1~0.5mA , plus 0.1Ω additional error

    wire resistance is excluded in the accuracy

    4KΩ0.0000~4.0000 KΩ0.1Ω0.01+0.01

    ±0.05~0.3mA simulate current

    wire resistance is excluded in the accuracy

    Thermal couple

    TC

    R*0°C~1767°C1°C

    0~100℃

    10~1767℃

    0~100℃

    100~1767℃

    1.5℃

    1.2℃

    1.5℃

    1.2℃

    Employ ITS-90 temperature standard


    Errors for cold-end compensation is excluded in the accuracy

    S*0°C~1767°C
    K-200.0°C~1372.0°C0.1°C

    -200.0~-100.0℃

    -100.0~400.0℃

    400.0~1200.0℃

    1200.0~1372.0℃

    0.6℃

    0.5℃

    0.7℃

    0.9℃

    E-200.0°C~1000.0°C

    -200.0~-100.0℃

    -100.0~600.0℃

    600.0~1000.0℃

    0.6℃

    0.5℃

    0.4℃

    J-200.0°C~1200.0°C

    -200.0~-100.0℃

    -100.0~800.0℃

    800.0~1200.0℃

    0.6℃

    0.5℃

    0.7℃

    T-250.0°C~400.0°C-250.0~400.0℃0.6℃
    N-200.0°C~1300.0°C

    -200.0~-100.0℃

    -100.0~900.0℃

    900.0~1300.0℃

    1.0℃

    0.7℃

    0.8℃

    B*600°C~1820°C1°C

    600~800℃

    800~1820℃

    1.5℃

    1.1℃

    L-200.0°C~900.0°C0.1°C

    -200.0~0.0℃

    0.0~900.0℃

    0.7℃

    0.5℃

    U-200.0°C~600.0°C0.1°C

    -200.0~0.0℃

    0.0~600.0℃

    0.7℃

    0.5℃

    resistance temperature

    RTD

    Pt100

    385

    -200.0°C~800.0°C0.1°C

    -200.0~0.0℃

    0.0~400.0℃

    400.0~800.0℃

    0.3℃

    0.5℃

    0.8℃

    Employ ITS-90 temperature standard


    Pt100,Cu50,Cu10 simulate current is: ±0.5~3mA

    when the simulate current is : ±0.1~0.5mA, add additional 0.5℃ error.


    Pt200,Pt500,Pt1000 simulate current is ±0.05~0.3mA

    wire resistance is excluded in the accuracy

    Pt200

    385

    -200.0°C~630.0°C

    -200.0~100.0℃

    100.0~300.0℃

    300.0~630.0℃

    0.8℃

    0.9℃

    1.0℃

    Pt500

    385

    -200.0°C~630.0°C

    -200.0~100.0℃

    100.0~300.0℃

    300.0~630.0℃

    0.4℃

    0.5℃

    0.7℃

    Pt1000

    385

    -200.0°C~630.0°C

    -200.0~100.0℃

    100.0~300.0℃

    300.0~630.0℃

    0.2℃

    0.5℃

    0.7℃

    Cu10-10.0°C~250.0°C1.8℃
    Cu50-50.0°C~150.0°C0.6℃

    frequency

    FREQ

    100Hz1.00 Hz ~110.00Hz0.01Hz±2 bytes

    1~11 Vp-p accuracy of square wave level

    ±5%reading +0.5V

    50% duty ratio

    load >100KΩ

    1KHz0.100 KHz ~1.100KHz1Hz±2 bytes
    10KHz1.0KHz~11.0KHz0. 1KHz±2 bytes
    50KHz10KHz~50KHz2KHz±5 bytes
    CPM60~1200 CPM1CPM±2CPM

    Pulse counting

    PULSE

    100Hz1~100000cycles1cyc±2 bytessee related index in frequency
    1KHz
    10KHz

    Switch volume

    SWITCH

    100Hz1.00Hz~110.00Hz0.01Hz±2 bytes

    see related index in frequency

    FET switch

    Max switch DC voltage/current: +28 V/50mA

    1KHz0.100KHz~1.100KHz1Hz
    10KHz1.0KHz~11.0KHz0.1KHz
    50KHz10KHz~50KHz2KHz
    Techincal Data
    ProjectModel
    Performance
    parameters
    VICTOR 26VICTOR 26H
    SourceDC millivoltRange-5 ~ 110mV-5 ~ 110mV
    Accuracy=
    ±(% of the set value+% of range)
    0.01%+0.01%0.01%+0.01%
    Resolution1uV1uV
    DC voltageRange-1 ~ 11V-1 ~ 11V
    Accuracy=
    ±(% of the set value+% of range)
    0.01%+0.01%0.01%+0.01%
    Resolution10uV/0.1mV10uV/0.1mV
    DC currentRange0 ~ 33mA0 ~ 33mA
    Accuracy=
    ±(% of the set value+% of range)
    0.01%+0.01%0.01%+0.01%
    Resolution1uA1uA
    Sink currentRange0 ~ 33mA0 ~ 33mA
    Accuracy=
    ±(% of the set value+% of range)
    0.01%+0.01%0.01%+0.01%
    Resolution1uA1uA
    External power
    supply
    5 ~ 28V5 ~ 28V
    ResistanceRange0 ~4KΩ0 ~4KΩ
    Accuracy=
    ±(% of the set value+% of range)
    0.01%+0.01%0.01%+0.01%
    Resolution0.01Ω/0.1Ω0.01Ω/0.1Ω
    ThermocoupleRangeR/S/K/E/J/T/B/N/L/UR/S/K/E/J/T/B/N/L/U
    Accuracy0.4℃0.4℃
    Resolution0.1℃/1℃0.1℃/1℃
    RTDRangePt100/Pt200/Pt500/
    Pt1000/Cu10/Cu50
    Pt100/Pt200/Pt500/
    Pt1000/Cu10/Cu50
    Accuracy0.2℃0.2℃
    Resolution0.1℃0.1℃
    Frequency
    (Hz)
    Range1Hz ~110KHz1Hz ~110KHz
    Accuracy±2words±2words
    Resolution0.01Hz/1Hz/0.1KHz/2KHz0.01Hz/1Hz/0.1KHz/2KHz
    Frequency(CMP)Range60~1200 CPM60~1200 CPM
    Accuracy±2words±2words
    Resolution1CPM1CPM
    PulseFrequency1Hz ~10KHz1Hz ~10KHz
    Range1 ~100000cyc1 ~100000cyc
    Accuracy±2words±2words
    Resolution1cyc1cyc
    SwitchRange1Hz ~110KHz1Hz ~110KHz
    Accuracy±2±2
    Resolution0.01Hz/1Hz/0.1KHz/2KHz0.01Hz/1Hz/0.1KHz/2KHz
    PressureRangeDepends on the pressure moduleDepends on the pressure module
    Accuracy=
    ±(% of the set value+% of range)
    Depends on the pressure moduleDepends on the pressure module
    Resolution5 digit display5 digit display
    MeasurementDC millivoltRange-5 ~ 550mV-5 ~ 550mV
    Accuracy=
    ±( % of Reading+ % of Range)
    0.01%+0.01%0.01%+0.01%
    Resolution1uV/10uV1uV/10uV
    DC voltageRange-0.5 ~ 35V-0.5 ~ 35V
    Accuracy=
    ±( % of Reading+ % of Range)
    0.01%+0.01%0.01%+0.01%
    Resolution0.1mV/1mV0.1mV/1mV
    DC currentRange-5 ~ 55mA-5 ~ 55mA
    Accuracy
    ±( % of Reading+ % of Range)
    0.01%+0.01%0.01%+0.01%
    Resolution1uA1uA
    ResistanceRange0 ~5.5KΩ0 ~5.5KΩ
    Accuracy=
    ±( % of Reading+ % of Range)
    0.01%+0.01%0.01%+0.01%
    Resolution0.01Ω/0.1Ω0.01Ω/0.1Ω
    ThermocoupleRangeR/S/K/E/J/T/B/N/L/UR/S/K/E/J/T/B/N/L/U
    Accuracy0.7℃0.7℃
    Resolution0.1℃/1℃0.1℃/1℃
    RTDRangePt100/Pt200/Pt500/
    Pt1000/Cu10/Cu50
    Pt100/Pt200/Pt500/
    Pt1000/Cu10/Cu50
    Accuracy0.4℃0.4℃
    Resolution0.1℃0.1℃
    Frequency
    (Hz)
    Range3Hz ~50KHz3Hz ~50KHz
    Accuracy±2words±2words
    Resolution0.01Hz0.01Hz
    Frequency(CMP)Range180~3000000 CPM180~3000000 CPM
    Accuracy±2words±2words
    Resolution1CPM1CPM
    SwitchRangeCLOSE/OPENCLOSE/OPEN
    Threshold200 ~300Ω200 ~300Ω
    PressureRangeDepends on the pressure moduleDepends on the pressure module
    Accuracy=
    ±( % of Reading+ % of Range)
    Depends on the pressure moduleDepends on the pressure module
    Resolution5 digit display5 digit display
    Continuity beeperRange0 ~500Ω0 ~500Ω
    Accuracy≤50Ωsound≤50Ωsound
    Resolution0.01Ω0.01Ω
    Loop power supplyRange24V24V
    Accuracy±10%±10%
    The maximum current22mA22mA
    HART×
    Other functions
    Backlight
    Auto Power-off
    Charging function
    Room temperature display
    Battery detection
    The ramp signal
    Communication functionRS232 serial communication, can realize remote control instrument by the device driver software.RS232 serial communication, can realize remote control instrument by the device driver software.
    Characteristic
    SafetyEN61010-1:2001EN61010-1:2001
    Withstand voltageThe input and output AC350V/1 minutesThe input and output AC350V/1 minutes
    InsulationThe input and output DC500V /50MΩ.The input and output DC500V /50MΩ.
    EMCEN61326-1:2006EN61326-1:2006
    AuthenticationCECE
    Display3.2“ TFT screen3.2“ TFT screen
    Power supply4×1.5V AA Alkaline battery4×1.5V AA Alkaline battery
    Size206 × 97 × 60 mm206 × 97 × 60 mm
    Weightabout 633gabout 633g
    Standard Quantity Per Carton6pcs6pcs
    Standard Carton Measurement530mm*405mm*310mm530mm*405mm*310mm
    Standard Carton Cross Weight12.6kg12.6kg

    Quality VICTOR 26 Multifunction Process Calibrator Signal Generator With Accuracy Of 0.01% 5 Digits Display 24V loop circuit IP65 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: XI'AN BEICHENG ELECTRONICS CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)