    Brand Name : VICTOR
    Model Number : VC3010
    Certification : CE
    Payment Terms : T/T, Western Union, L/C, Paypal
    Supply Ability : 10000pcs available
    Delivery Time : 5 to 30 days
    Price : USD8/pc
    • Product Details
    • Company Profile

    Digital Pocket Analog Multimeter 10A 1000V With Resistance Function

    Digital Pocket Analog Multimeter 10A 1000V With Resistance Function


    VC3010 Analog Multimeter Large Lcd Display 1000V 10A 10kΩ

    SAFETY INFORMATION

    1. Never use meter on the electric circuit that exceed 3kVA.
    2. Pay special attention when measuring the voltage of AC30 Vrms or DC 60V or more to avoid injury.
    3. Never apply an input signals exceeding the maximum rating input value.
    4. Never user meter for measuring line connected with equipment (i.e. motors) that generates induced or surge voltage since it may exceed the maximum allowable voltage.
    5. Never use meter if the meter or test leads are damaged or broken.
    6. To ensure safety and maintain accuracy, calibrate and check the meter at least once a year.
    7. Never use uncased meter
    8. Be sure to use a fuse of the specified rating or type. Never use a substitute of the fuse or never made a short circuit of the fuse.
    9. Always keep your fingers behind the finger guards on the probe when making measurements.
    10. Be sure to disconnect the test pins from the circuit when changing the function or range.
    11. Before starting measurement, make sure that the function and range are property set in accordance with the measurement.
    12. Never use meter with wet hands or in a damp environment.
    13. Never use test leads other than the specified test leads.
    14. Never open tester case except when replacing batteries or fuses. Do not attempt any alteration of original specifications.


    SPECIFICATIONS
    General Specification

    ItemSpecification
    Circuit protectionThe circuit is protected by fuse even when voltage of up to AC 230V is impressed on each range for 5 seconds.
    Internal batteryR6 (IEC) or UM-3 1.5Vx2, 9V6F22.
    Internal fuse0.5A/250V, Φ5.2mm X 20mm.

    Standard calibration temp
    And humidity range

    23±2℃ 45∽75% RH

    Operating temperature
    And humidity range.

    0∽40℃, 80%RH max. No condensation
    Withstand voltage3kV AC(1min) between input terminal and case.
    Dimensions and weight154x104x34mm 291g(include battery)
    AccessoriesOne copy of instruction manual, Test leads


    Measurement Range and Accuracy

    FunctionFull scale valueAccuracyRemarks
    DCV

    2.5/10/25/50/250
    /1kV

    ±3%against
    full scale

    Input impedance
    20kΩ/V

    ACV10/50/250/1kV

    ±4% against
    full scale

    Input impedance
    9kΩ/V

    DCA

    50μA
    0.5/5/50/500mA

    ±3% against
    full scale

    *1
    Voltage drop 0.1V

    10AVoltage drop 0.13V
    Ω

    x1/x10/x100/x1k
    /x10k

    ±3%of arcCenter value 20Ω
    DB

    -10∽+22d
    (for 10V AC)
    ∽+62dB

    _____

    Input impedance
    9kΩ/V

    Beep
    HFE0∽1000

    *Not including the resistance of the fuse .

    Preparation for Measurement

    1. Adjustment of meter zero position:

    Turn the zero position adjuster so that the pointer may align right to the zero position.

    1. Range selection:

    Select a range proper for the item to be measured set range selector knob according.


    NOTE
    When determining a measuring range, select such one for higher voltage then the value to be measured as well as where the pointer of a meter moves to a considerable extent.
    However, select the maximum range and measure in case the extent of value to be measured can nor be predicted.


    • Measuring DCV
    1. Set the range selector knob to an appropriate DCV range.
    2. Apply the black test pin to the minus potential of measured circuit and the red test pin to the plus potential.
    3. Read the move of the pointer by DC/AC scale.
    ArcRangeMultipleArcRangeMultiple
    1X10kX10k4DCV250VX1
    X1kX1kDCV25VX0.1
    X100X100DCV2.5VX0.01
    X10X10ACV250VX1
    X1X15DCA10AX1
    2DCV1000VX16dB
    DCV10VX1ACV10VX1
    ACV1000VX1ACV50V+14
    ACV10VX1ACV250V+28
    3DCV50VX1ACV1000V+40
    ACV50VX17hFEX1
    DCA500mAX10
    DCA50mAX1
    DCA5mAX0.1
    DCA0,5mAX0.01
    DCA500μAX10